PIcon Program & Report
Rev 2.0 June 2006
Page 20
Hose Selection — After the dispenser number is chosen, Hose 1 is indicated on the
display. From this point, the following parameters may be set for Hose 1. If
programming a multi-product dispenser, parameters must be set for all hoses.
Product — Press the <GRADE> key to scroll to the desired product for the current
hose displayed. During this step, pressing the <AUTHORIZE> key will clear the
product number for reentry.
Service — To select service type, press the <CHNG> key to toggle between full-
or self-service for the specified dispenser. Setting service type on one hose selects
it for the entire dispenser.
Blend — If the dispenser is a blending dispenser, on the numeric keypad enter the
amount, in percent of hose 1, to be dispensed by the selected hose. Press
<ENTER>. (Default is set at 0.) Remember that any data entered on the numeric
keypad will appear on the display.
Slowdown Amount — To set slowdown amount, enter new value on the numeric
keypad. Press <PUMP STOP>. Setting slowdown amount on one hose sets it for
the entire dispenser. Default is 15 cents. Maximum is 99 cents.
If the dispenser is a multi-product dispenser, press <SELECT> to scroll to the next hose to
be programmed. Follow this procedure to program each hose of each dispenser at the site.
To exit Mode 1, press the <MNGR> key. The PIcon display returns to M 0, the mode entry
prompt. To exit programming mode completely, press the <MNGR> key again. The PIcon
will return to operator mode.